GTA02A5 Boot without battery

From Openmoko

(Difference between revisions)
Jump to: navigation, search
(New page: The GTA02A6 boots without battery (at least using NOR), but the GTA02A5 does not. The reason is that C1767 was changed in A6. Here are some hints for replacing it: C1767 is only sized 080...)
 
 
(4 intermediate revisions by one user not shown)
Line 2: Line 2:
 
The reason is that C1767 was changed in A6.  
 
The reason is that C1767 was changed in A6.  
 
Here are some hints for replacing it:
 
Here are some hints for replacing it:
C1767 is only sized 0805 or 0603, so you have
+
C1767 is only sized 0805 or 0603 on A5, so you have
 
to add another cap in parallel. Fortunately there
 
to add another cap in parallel. Fortunately there
 
is a bit of empty space on the pcb near C1764.
 
is a bit of empty space on the pcb near C1764.
 
I have taken 587-1963-1-ND CAP CER 100UF 6.3V X5R 1206
 
I have taken 587-1963-1-ND CAP CER 100UF 6.3V X5R 1206
 
from digikey.
 
from digikey.
One side of the new cap goes to the GND side of c1706
+
One side of the new cap goes to the GND side of c1706
 
and you have to take care not to touch c1729 and tp1704
 
and you have to take care not to touch c1729 and tp1704
 
the other side of the cap ends in the middle of c1764 (which was rotated by 90 degrees between A5 and A6.
 
the other side of the cap ends in the middle of c1764 (which was rotated by 90 degrees between A5 and A6.
Line 14: Line 14:
 
Keep care that the isolation strip is still over the various 1206 sized
 
Keep care that the isolation strip is still over the various 1206 sized
 
pieces.
 
pieces.
 +
 +
The picture shows the place and wire to the new C1767 in red, the old C1767 is marked in magenta
 +
 +
[[Image:C1767-reworked.jpg]]
 +
 +
[[Category:Neo FreeRunner reworks and mods]]

Latest revision as of 13:55, 18 October 2009

The GTA02A6 boots without battery (at least using NOR), but the GTA02A5 does not. The reason is that C1767 was changed in A6. Here are some hints for replacing it: C1767 is only sized 0805 or 0603 on A5, so you have to add another cap in parallel. Fortunately there is a bit of empty space on the pcb near C1764. I have taken 587-1963-1-ND CAP CER 100UF 6.3V X5R 1206 from digikey. One side of the new cap goes to the GND side of c1706 and you have to take care not to touch c1729 and tp1704 the other side of the cap ends in the middle of c1764 (which was rotated by 90 degrees between A5 and A6. and is connected using a short wire to R1767.

Keep care that the isolation strip is still over the various 1206 sized pieces.

The picture shows the place and wire to the new C1767 in red, the old C1767 is marked in magenta

C1767-reworked.jpg

Personal tools

The GTA02A6 boots without battery (at least using NOR), but the GTA02A5 does not. The reason is that C1767 was changed in A6. Here are some hints for replacing it: C1767 is only sized 0805 or 0603, so you have to add another cap in parallel. Fortunately there is a bit of empty space on the pcb near C1764. I have taken 587-1963-1-ND CAP CER 100UF 6.3V X5R 1206 from digikey.

One side of the new cap goes to the GND side of c1706

and you have to take care not to touch c1729 and tp1704 the other side of the cap ends in the middle of c1764 (which was rotated by 90 degrees between A5 and A6. and is connected using a short wire to R1767.

Keep care that the isolation strip is still over the various 1206 sized pieces.